Freeze time = Thermistor reads 26.6ºF (-3ºC) then completes 8 minute Freeze cycle completion timer.

Freeze time = Thermistor reads 26.6ºF (-3ºC) then completes 8 minute Freeze cycle completion timer.

- 26 -

Harvest time = Thermistor reads 44.6ºF (+7ºF) then completes 50 second defrost completion timer.