Image 8
The AM series uses a thermostatic bin control located on the right rear side of the ice storage compartment. This control will open when ice touches the sensing bulb and the unit will shut down

The AM series uses a thermostatic bin control located on the right rear side of the ice storage compartment. This control will open when ice touches the sensing bulb and the unit will shut down

This control includes a small heater to eliminate the control opening due to low ambient temperatures in the bin.

Access the control by removing the wiring channel from the rear of the unit.

The thermostatic bin control is factory set and should shut down the unit within 10 seconds after ice contacts the bulb. Adjustment may be necessary in higher altitudes.