Hoshizaki AM-50BAE 4A3207-01 1/2” FPT 4A3240-01, AM-50through April 2004 1/2” FPT AM-50from May

Models: AM-50BAE

1 31
Download 31 pages 60.32 Kb
Page 3
Image 3
4A3207-01

WATER INLET CONNECTIONS 3/8” Male flare

4A3207-01

1/2” FPT

4A3240-01

DRAIN CONNECTIONS 5/8” I.D. rubber hose

(AM-50 through April

2004)

1/2” FPT

AM-50 from May 2004

3/4” MPT

(AM-100 & AM-150)

A standard 120-volt power cord provides the electrical connection. The unit is designed to operate on a separate 15-amp circuit.

Inlet Water Line Connection

1st production units had a 3/4" BSP connection directly to the inlet water valve. (DO not connect with 3/4" FIP)

Fitting (4A3207-01) and gasket 413854-01 were used from May through July production. (Through August on the AM-100BAE and AM- 150 BAF)

Fitting (4A3240-01) and gasket 413854-01 were added in August 03 on the AM-50BAE and September 03 on the AM-100BAE and AM- 150BAF.

If no fitting is included, order either fitting /gasket above or use 3/4" hose type fitting to make this connection.

A minimum 3/8” water line is required for proper operation.

Drain line connection

The drain connection for the AM-50 was 5/8” I.D. hose until April of 2004 and was located on the left rear of the unit. A standard 3/4” male insert fitting can be used to connect this drain. From May 2004 the drain fitting is 1/2” FPT. A minimum 1/2” I.D. vented drain is required when making this connection.

The drain for the AM-100 and AM-150 is a 3/4” MPT.

Since the unit will likely be enclosed, it is recommended to use flexible, supply and drain connections. This will allow easy removal if service is necessary.

- 3 -

Page 3
Image 3
Hoshizaki AM-50BAE 4A3207-01 1/2” FPT 4A3240-01, AM-50through April 2004 1/2” FPT AM-50from May, 3/4” MPT AM-100& AM-150