Problem

Possible Cause

Remedy

[1] No ice dispensed.

a) Power Supply

1. "OFF" position.

1.

Move to "ON" position.

 

 

 

 

 

 

 

 

2.

Loose connection.

2.

Tighten.

 

 

 

 

 

 

 

 

3.

Bad contacts.

3.

Check for continuity and

 

 

 

 

 

replace.

 

 

 

 

 

 

 

 

4.

Voltage too high.

4.

Check and get

 

 

 

 

 

recommended voltage.

 

 

 

 

 

 

b) Fuse (Inside Fused

1. Blown.

1.

Check for short circuit and

 

Disconnect, if any)

 

 

 

replace.

 

 

 

 

 

 

c) Spout Switch

1. Bad contacts.

1.

Check for continuity and

 

 

 

 

 

replace.

 

 

 

 

 

 

 

 

2.

Loose connection.

2.

Tighten.

 

 

 

 

 

 

d) Door Switch

1. Front panel is not in

1.

Place in position.

 

 

 

position.

 

 

 

 

 

 

 

 

 

 

2.

Actuating plate does not

2.

Check for continuity and

 

 

 

push door switch.

 

adjust.

 

 

 

 

 

 

 

 

3.

Bad contacts.

3.

Check for continuity and

 

 

 

 

 

replace.

 

 

 

 

 

 

 

 

4.

Loose connection.

4.

Tighten.

 

 

 

 

 

 

 

e) Safety Switch

1.

Spout is not in position.

1.

Check for continuity and

 

 

 

 

 

place in position.

 

 

 

 

 

 

 

 

2.

Bad contacts.

2.

Check for continuity and

 

 

 

 

 

replace.

 

 

 

 

 

 

 

 

3.

Loose connection.

3.

Tighten.

 

 

 

 

 

 

f) Gear Motor

1. Thermal protector is

1.

Allow to cool.

 

 

 

tripped.

 

 

 

 

 

 

 

 

 

 

2.

Gear motor winding

2.

Replace.

 

 

 

opened.

 

 

 

 

 

 

 

 

 

 

3.

Bearing worn out.

3.

Replace.

 

 

 

 

 

 

 

 

4.

Wiring to gear motor.

4.

Check for loose connection

 

 

 

 

 

or open circuit, and replace

 

 

 

 

 

wiring as needed.

 

 

 

 

 

 

 

 

5.

Defective capacitor.

5.

Replace.

 

 

 

 

 

 

 

 

6.

Agitator rotates in

6.

Check leads and reverse the

 

 

 

reverse direction.

 

connections.

 

 

 

 

 

 

g) Solenoid

1. Solenoid winding open.

1.

Replace

 

 

 

 

 

 

 

 

2.

Wiring to solenoid.

2.

Check for loose connection

 

 

 

 

 

or open circuit, and replace

 

 

 

 

 

wiring as needed.

 

 

 

 

 

 

 

 

3.

Overload due to

3.

After tightening, apply

 

 

 

loosening screws.

 

thread sealant to the parts.

 

 

 

 

 

 

7