Juniper Networks

NetScreen Release Notes

 

 

01998 – You could not save the set console aux disable command into the device configuration.

01739 – Ping operations would not work if fast aging out of MAC addresses did not occur when a PC migrated from one Juniper NetScreen-5GT port to another in the same zone.

01635 – The system failed when an H323 recomputed a UDP checksum; the UDP packet lengths sometimes were too consistent with the IP lengths.

01584 – If a virtual routing instance acted as the ABR (area border router), then the routing instance did not advertise inter-area summary routes. An inter-area summary route is one value that encompasses a range of route prefixes contained in multiple routing areas.

01523 – An OSPF virtual routing instance sometimes unexpectedly dropped routes.

4.2Addressed Issues from ScreenOS 5.0.0r8

40292 – A potential cross-site scripting attack existed in the anti-virus scan engine when processing compressed files.

39458 – You could not configure 16 concurrent anti-virus messages, the expected maximum number of messages allowed when running the anti- virus Scan Manager utility in the WebUI.

39087 – In certain circumstances, the first attempt to access a TCP application through a Juniper NetScreen-5000 system with authentication failed when the ARP entry for the application was not present.

38193 – A Juniper NetScreen-5GT could not access common public web sites when an administrator performed an anti-virus scan for HTTP on the device. The attempted connections will expire after they exceed the time out threshold for connection attempts.

37933, 37945 – If a number of different attacks entered the Juniper NetScreen-5000 Series system over a period of time, the system sometimes began to drop packets.

36708 – You could not view the traffic logs for a Vsys if you entered the Vsys as a root admin user.

36670 – You could create more VLANs on a Juniper Networks security appliance than the number of VLANs the device officially supported. However, doing this sometimes caused unexpected results. Refer to the specifications sheet for your NetScreen product to learn how many VLANs it supports.

36494 – Upon startup, Juniper Networks security appliances using PPPoE sometimes generated a warning message informing that the interface gateway command was invalid. This is a result of the gateway changing

ScreenOS 5.0.0r9-FIPS

P/N 093-1638-000, Rev. A

Page 13 of 42

Page 13
Image 13
Juniper Networks 208, 5200, 204, 500, 5XT, 5400 manual Addressed Issues from ScreenOS 5.0.0r8