9)In bad or severe water conditions, clean the float switch assembly as described below. Otherwise, continue to step 10.

a.Remove the float switch assembly from the reservoir cover.

b.Wipe down the float switch assembly with the cleaning solution.

c.Rinse the float switch assembly thoroughly with clean water.

d.Replace the float switch assembly in its correct position.

10)Move the power switch to the "ON" position and replace the panels in their correct positions. Turn on the power supply, then move the control switch to the "ICE" position.

Make ice using the solution until the icemaker stops making ice. Note: This unit will not run if the safety switch is not engaged.

11)Move the control switch to the "DRAIN" position. Allow the water system to drain for

5minutes.

12)Move the control switch to the "ICE" position. Open the icemaker water supply line shut‑off valve to supply water to the reservoir.

13)After the gear motor starts, move the control switch to the "DRAIN" position. Allow the water system to drain for 5 minutes.

Note: If you do not sanitize the unit, move the control switch to the "ICE" position after the water system drains. Allow the icemaker to run for 30 minutes, then move the control switch to the "OFF" position. Turn off the power supply, then remove the front panel and storage bin cover. Move the power switch to the "OFF" position. Go to step 12 in "III.A.2.c) Cleaning and Sanitizing Procedure" under "Dispensing Components."

14)Move the control switch to the "OFF" position, then turn off the power supply.

15)Close the icemaker water supply line shut-off valve.

c)Sanitizing Solution

Dilute 0.82 fl. oz. (25 ml) of a 5.25% sodium hypochlorite solution (chlorine bleach) with

1.6gal. (6.0 l) of warm water.

d)Sanitizing Procedure - Following Cleaning Procedure

1)Make sure the control switch is in the "OFF" position, the power supply is off, and the icemaker water supply line shut‑off valve is closed.

2)Remove the front and top panels, then move the power switch to the "OFF" position.

3)Remove the storage bin cover. Remove spout B, then remove spout A.

4)Pour the sanitizing solution over the extruding head until the evaporator assembly and the reservoir are full and the solution starts to overflow into the drain pan.

5)Replace spout A, spout B, and the storage bin cover in their correct positions.

6)Allow the icemaker to sit for 10 minutes before operation.

7)Move the power switch to the "ON" position and replace the panels in their correct positions. Turn on the power supply, then move the control switch to the "ICE" position.

Make ice using the solution until the icemaker stops making ice.

8)Move the control switch to the "DRAIN" position. Allow the water system to drain for

5 minutes.