1. Icemaker

1. Icemaker

Icemaker water supply inlet is 1/2" female pipe thread (FPT). A minimum of 1/4" nominal

ID copper water tubing or equivalent is required for the icemaker water supply line.

An icemaker water supply line shut-off valve and drain valve should be installed.

Storage bin and drip tray drain outlets are 3/4" FPT. A minimum of 3/4" nominal ID hard pipe or equivalent is required for the storage bin and drip tray drain lines.

Icemaker

Icemaker Water Supply

Icemaker Water Line Shut-Off Valve

Supply Inlet

1/2" FPT

Minimum 1/4"

Nominal ID Copper

Water Tubing

Drip Tray

Vent

Icemaker Water Supply

Drain Outlet

Tube

3/4" FPT

Line Drain Valve

 

Storage Bin

 

Drain Outlet

Stand

3/4" FPT

 

Separate piping to approved drain. Leave a 2-inch (5‑cm) vertical air gap between the end of each pipe and the drain.

Minimum 3/4" Nominal ID

 

2-inch (5-cm)

 

air gap

Hard Pipe

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DCM-300BAH(-OS)

Floor Drain

Fig. 4