2.3 Power Supply Troubleshooting

2 Troubleshooting Procedures

Procedure 2 Error Code Check

If the power supply microprocessor detects a malfunction, it indicates the error code as shown below.

The error code begins with the least significant digit.

 

Table 2-3 Error code

 

 

Error code

Where Error occurs

 

 

1*h

AC Adaptor

 

 

2*h

1st Battery

 

 

3*h

2nd Battery

 

 

4*h

S3V output

 

 

5*h

E5V output

 

 

6*h

E3V output

 

 

7*h

1R5-E1V output

 

 

8*h

1R8-B1V output

 

 

9*h

PPV output

 

 

A*h

PTV output

 

 

B*h

1R5-E1V output

 

 

C*h

1R8-B1V output

 

 

D*h

PPV output

 

 

E*h

PTV output

 

 

F*h

-

 

 