2 Troubleshooting Procedures | 2.3 Power Supply Troubleshooting | |||
PPV output |
|
|
| |
|
|
|
|
|
| Error code |
| Meaning |
|
|
|
|
| |
| 90h | PPV voltage is over 1.80V when the computer is powered on/off. |
| |
|
|
|
| |
| 91h | PPV voltage is under 0.32V when the computer is powered on. |
| |
|
|
|
| |
| 92h | PPV voltage is under 0.32V when the computer is booting up. |
| |
|
|
|
|
|
PTV output |
|
|
| |
|
|
|
| |
| Error code |
| Meaning |
|
|
|
|
| |
| A0h | PTV voltage is over 1.26V when the computer is powered on/off. |
| |
|
|
|
| |
| A1h | PTV voltage is under 0.89V when the computer is powered on. |
| |
|
|
|
| |
| A2h | PTV voltage is under 0.89V when the computer is booting up. |
| |
|
|
|
|
|
1R5-E1V output
Error code | Meaning |
|
|
B0h | |
|
|
B1h | |
|
|
B2h | |
|
|
B4h | |
| OUTV7=EV is designated. |
1R8-B1V output
Error code | Meaning |
|
|
C0h | |
|
|
C1h | |
|
|
C2h | |
|
|
C4h | |
| OUTV8=BV is designated. |
PPV output
Error code | Meaning |
|
|
D0h | PPV voltage is over 1.80V when the computer is powered on/off. |
|
|
D1h | PPV voltage is under 0.32V when the computer is powered on. |
|
|
D2h | PPV voltage is under 0.32V when the computer is booting up. |
|
|
[CONFIDENTIAL] | PORTEGE R500 Maintenance Manual |