3.22 Log Utilities

3 Tests and Diagnostics

3.22.2 Operations

1.Select 5 and press Enter in the DIAGNOSTIC MENU, the error information is displayed in the following format:

XXXXX ERRORS

PASS STS

ADDR

WD RD HSTS [ERROR STATUS NAME]

CNT

TS-NO

001

FDD 02

0000 103

00001

00 00 0000 FDD-WRITE PROTECTED

001

FDD 01

0000 180

00001

00 00 0000 FDD-TIME OUT ERROR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Address

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HDC status

 

 

 

 

 

 

 

 

Error status

 

 

 

 

 

 

 

 

 

 

Pass count

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read data

 

 

 

 

 

Subtest number

 

 

 

Write data

 

Error status name

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test name

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error count

 

 

 

 

 

 

 

 

 

 

 

[[1:Next,2:Prev,3:Exit,4:Clear,5:Print,6:FD Log Read,7:FD Log Write]]

2.The error information displayed on the screen can be manipulated by the following number keys:

The 1 key scrolls the display to the next page. The 2 key scrolls the display to the previous page. The 3 key returns to the Diagnostic Menu.

The 4 key erases all error log information in RAM. The 5 key outputs the error log information to a printer. The 6 key reads the log information from a floppy disk. The 7 key writes the log information to a floppy disk.

3.In the case of “error retry OK”, a capital “R” will be placed at the beginning of the error status. However, it is not added to the error count.