2.3 Power Supply Troubleshooting | 2 Troubleshooting Procedures | |||
E5V output |
|
|
| |
|
|
|
|
|
| Error code |
| Meaning |
|
|
|
|
| |
| 50h | E5V voltage is over 6.00V when the computer is powered on/off. |
| |
|
|
|
| |
| 51h | E5V voltage is under 4.50V when the computer is powered on. |
| |
|
|
|
| |
| 52h | E5V voltage is under 4.50V when the computer is booting up. |
| |
|
|
|
| |
| 54h | E5V voltage is under 4.50V when EV power is maintained and |
| |
|
| OUTV1=EV is designated. |
|
|
E3V output |
|
|
| |
|
|
|
| |
| Error code |
| Meaning |
|
|
|
|
| |
| 60h | E3V voltage is over 3.96V when the computer is powered on/off. |
| |
|
|
|
| |
| 61h | E3V voltage is under 2.81V when the computer is powered on. |
| |
|
|
|
| |
| 62h | E3V voltage is under 2.81V when the computer is booting up. |
| |
|
|
|
| |
| 64h | E3V voltage is under 2.81 V when EV power is maintained. |
| |
|
|
|
|
|
1R5-E1V output
Error code | Meaning |
|
|
70h | |
|
|
71h | |
|
|
72h | |
|
|
1R8-B1V output
Error code | Meaning |
|
|
80h | |
|
|
81h | |
|
|
82h | |
|
|
84h | |
| OUTV4=BV is designated. |
|
|