8)Remove the spout cover, ice dispensing spout, and water dispensing nozzle. See Fig. 9.

9)Immerse the agitator, dispensing auger, and parts removed in steps 5 through 8 in the cleaning solution and then in the sanitizing solution for 15 minutes each. Rinse the parts thoroughly with clean water. On Opti-Serve models (-OS), wipe the optical sensors with cleaning solution and then with a clean, damp cloth.

10)Wipe the shutter located above the ice dispensing spout thoroughly with a clean cloth.

11)Reassemble the bin control assembly and replace all parts in the reverse order of which they were removed.

12)Pour warm water into the storage bin and melt any remaining ice. Clean the storage bin liner and the storage bin cover using a neutral cleaner. Rinse thoroughly after cleaning. Replace the storage bin cover in its correct position.

13)Move the power switch to the "ON" position, then replace the panels in their correct positions. Turn on the power supply, then move the control switch to the "ICE" position to start the automatic icemaking process.

Water Dispensing Nozzle

Ice Dispensing Spout

Spout Cover

Fig. 9

22

Page 22
Image 22