III. Cleaning and Maintenance
WARNING
CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after any cleaning or maintenance is done to the unit. Make sure that none have fallen into the storage bin.
A. Cleaning and Sanitizing Instructions
Hoshizaki recommends cleaning and sanitizing this unit at least twice a year. More frequent cleaning and sanitizing, however, may be required in some existing water conditions.
WARNING
1.To prevent injury to individuals and damage to the icemaker, do not use ammonia type cleaners.
2.Carefully follow any instructions provided with the bottles of cleaning and sanitizing solution.
3.Always wear
4.After cleaning and sanitizing, do not use ice made from the cleaning and sanitizing solutions. Be careful not to leave any solution on the parts or in the storage bin.
1. Cleaning Solution
IMPORTANT
For safety and maximum effectiveness, use the solution immediately after dilution.
Dilute 4.8 fl. oz. (142 ml) of Hoshizaki "Scale Away" with 0.8 gal. (3 l) of warm water. This is a minimum amount. Make more solution if necessary.
| Proximity Switch |
|
|
| Packing | Bin Control Assembly Mount | |
Strap | Actuator | ||
| Shaft |
| |
Spout |
|
| |
|
|
| |
|
| Plate | Chute Insulation |
|
|
| |
Packing |
|
|
|
Extruding Head | Baffle |
| Ties |
|
|
| |
Evaporator | Chute |
|
|
Assembly |
|
|
|
| Reservoir | Packing |
|
|
|
|
Fig. 6