Hoshizaki F-80 I MWH (-c), F-80 I MAH (-c) service manual F-801MWH, Water Flow For Condenser

Models: F-80 I MAH (-c) F-80 I MWH (-c)

1 58
Download 58 pages 38.42 Kb
Page 30
Image 30

F-801MWH

APPROXIMATE

Ambient

 

 

 

 

Water Temp.

 

(F)

 

ICE PRODUCTION

Temp. (F)

 

50

 

 

70

 

 

 

90

 

PER 24 HR.

70

*

720

(327)

 

693

(315)

 

 

677

(307)

 

80

 

661

(300)

 

646

(293)

 

 

630

(286)

 

90

 

616

(279)

*

605

(274)

 

 

587

(266)

lbs./day ( kg/day)

100

 

573

(260)

 

560

(254)

 

*

520

(236)

APPROXIMATE ELECTRIC

70

*

1076

--

 

1076

--

 

 

1076

--

CONSUMPTION

80

 

1076

--

 

1077

--

 

 

1077

--

 

90

 

1077

--

*

1078

--

 

 

1076

--

watts

100

 

1074

--

 

1071

--

 

*

1069

--

APPROXIMATE WATER

70

*

306

(1158)

 

397

(1504)

 

 

631

(2387)

CONSUMPTION PER 24 HR.

80

 

318

(1205)

 

415

(1571)

 

 

666

(2520)

(TOTAL)

90

 

331

(1251)

*

433

(1638)

 

 

704

(2666)

gal. / day (l/day)

100

 

344

(1304)

 

457

(1728)

 

*

778

(2944)

EVAPORATOR OUTLET TEMP.

70

*

17

(-8)

 

17

(-8)

 

 

18

(-8)

°F (°C)

80

 

19

(-7)

 

19

(-7)

 

 

20

(-7)

 

90

 

20

(-7)

*

20

(-7)

 

 

20

(-7)

 

100

 

20

(-7)

 

20

(-7)

 

*

21

(-6)

HEAD PRESSURE

70

*

265

(18.6)

 

265

(18.6)

 

 

266

(18.7)

 

80

 

265

(18.6)

 

265

(18.6)

 

 

266

(18.7)

PSIG (kg/cm2G)

90

 

265

(18.6)

*

265

(18.6)

 

 

266

(18.7)

100

 

265

(18.6)

 

265

(18.6)

 

*

266

(18.7)

SUCTION PRESSURE

70

*

42

(3.0)

 

43

(3.0)

 

 

44

(3.1)

PSIG (kg/cm2G)

80

 

42

(3.0)

 

43

(3.0)

 

 

44

(3.1)

 

90

 

42

(3.0)

*

43

(3.0)

 

 

44

(3.1)

 

100

 

42

(3.0)

 

43

(3.0)

 

*

44

(3.1)

WATER FLOW FOR CONDENSER

 

15 gal/h (AT 90°F / WT 70°F)

 

 

 

PRESSURE DROP OF COOLING WATER LINE

Less than 7 PSIG

 

 

 

 

 

 

HEAT OF REJECTION FROM CONDENSER

5155 BTU/h (AT 90°F / WT 70°F)

 

 

 

HEAT OF REJECTION FROM COMPRESSOR

1050 BTU/h (AT 90°F / WT 70°F)

 

 

 

Note: The data without *marks should be used for reference.

We reserve the right to make changes in specifications and design without prior notice.

30

Page 30
Image 30