Hoshizaki F-80 I MWH (-c), F-80 I MAH (-c) service manual F-801MWH-C

Models: F-80 I MAH (-c) F-80 I MWH (-c)

1 58
Download 58 pages 38.42 Kb
Page 32
Image 32

F-801MWH-C

APPROXIMATE

Ambient

 

 

 

 

Water Temp.

 

(F)

 

ICE PRODUCTION

Temp. (F)

 

50

 

 

70

 

 

 

90

 

PER 24 HR.

70

*

645

(293)

 

620

(281)

 

 

608

(276)

 

80

 

596

(270)

 

585

(265)

 

 

574

(260)

 

90

 

563

(255)

*

550

(249)

 

 

541

(246)

lbs./day ( kg/day)

100

 

531

(241)

 

521

(236)

 

*

485

(220)

APPROXIMATE ELECTRIC

70

*

1083

--

 

1082

--

 

 

1081

--

CONSUMPTION

80

 

1080

--

 

1078

--

 

 

1077

--

 

90

 

1076

--

*

1075

--

 

 

1073

--

watts

100

 

1072

--

 

1070

--

 

*

1068

--

APPROXIMATE WATER

70

*

276

(1046)

 

342

(1294)

 

 

579

(2192)

CONSUMPTION PER 24 HR.

80

 

287

(1086)

 

354

(1339)

 

 

605

(2291)

(TOTAL)

90

 

296

(1119)

*

368

(1392)

 

 

633

(2397)

gal. / day (l/day)

100

 

305

(1156)

 

381

(1442)

 

*

693

(2622)

EVAPORATOR OUTLET TEMP.

70

*

20

(-7)

 

20

(-7)

 

 

21

(-6)

°F (°C)

80

 

21

(-6)

 

21

(-6)

 

 

21

(-6)

 

90

 

21

(-6)

*

21

(-6)

 

 

21

(-6)

 

100

 

21

(-6)

 

21

(-6)

 

*

22

(-6)

HEAD PRESSURE

70

*

263

(18.5)

 

263

(18.5)

 

 

264

(18.6)

 

80

 

263

(18.5)

 

263

(18.5)

 

 

264

(18.6)

PSIG (kg/cm2G)

90

 

263

(18.5)

*

263

(18.5)

 

 

264

(18.6)

100

 

263

(18.5)

 

263

(18.5)

 

*

264

(18.6)

SUCTION PRESSURE

70

*

46

(3.2)

 

46

(3.3)

 

 

47

(3.3)

PSIG (kg/cm2G)

80

 

46

(3.2)

 

46

(3.3)

 

 

47

(3.3)

 

90

 

46

(3.2)

*

46

(3.3)

 

 

47

(3.3)

 

100

 

46

(3.2)

 

46

(3.3)

 

*

47

(3.3)

WATER FLOW FOR CONDENSER

 

13 gal/h (AT 90°F / WT 70°F)

 

 

 

PRESSURE DROP OF COOLING WATER LINE

Less than 7 PSIG

 

 

 

 

 

 

HEAT OF REJECTION FROM CONDENSER

5155 BTU/h (AT 90°F / WT 70°F)

 

 

 

HEAT OF REJECTION FROM COMPRESSOR

1050 BTU/h (AT 90°F / WT 70°F)

 

 

 

Note: The data without *marks should be used for reference.

We reserve the right to make changes in specifications and design without prior notice.

32

Page 32
Image 32
Hoshizaki F-80 I MWH (-c), F-80 I MAH (-c) service manual F-801MWH-C