3. Maintenance

3. Maintenance

IMPORTANT

1.This icemaker must be maintained individually, referring to the instruction manual and labels provided with the icemaker.

2.To have the optimum performance of this icemaker, the following consumable parts need periodical inspection, maintenance and replacement:

Extruding Head Housing Gear Motor Auger Mechanical Seal

These parts should be inspected at least once a year or every 10,000 hours of operation. Their service life, however, depends on water quality and environment. More frequent inspection and maintenance are recommended.

Consult with your local distributor about inspection and maintenance service. To obtain the name and phone number of your local distributor, call Hoshizaki Technical Support at 1-800-233-1940.

1) Stainless Steel Exterior

To prevent corrosion, wipe the exterior occasionally with a clean and soft cloth. Use a damp cloth containing a neutral cleaner to wipe off oil or dirt build up.

2)Storage Bin and Scoop

*Wash your hands before removing ice. Use the plastic scoop provided (bin accessory).

*The storage bin is for ice use only. Do not store anything else in the bin.

*Keep the scoop clean. Clean using a neutral cleaner and rinse thoroughly.

*Clean the bin liner using a neutral cleaner. Rinse thoroughly after cleaning.

57

Page 57
Image 57
Hoshizaki F-80 I MAH (-c), F-80 I MWH (-c) service manual Maintenance