27)When replacing the evaporator;

26) Assemble the removed parts in the reverse order of the above procedure.

WARNING

Be careful not to scratch the surface of the O-ring, or it may cause water leaks. Handle the mechanical seal with care not to scratch nor to contaminate its contact surface.

27)When replacing the evaporator;

(a)Braze the new evaporator with nitrogen gas flowing at the pressure of 3 - 4 PSIG.

(b)Replace the drier.

(c)Check for leaks using nitrogen gas (140 PSIG) and soap bubbles.

(d)Evacuate the system. Charge it with refrigerant. For the air-cooled and water-cooled models, see the nameplate for required refrigerant charge and type. For the remote air-cooled models, see the label on the control box.

28)Move the flush switch to the "ICE" position.

29)Replace the panels in their correct position.

30)Turn on the power supply.

47

Page 47
Image 47
Hoshizaki F-80 I MAH (-c) When replacing the evaporator, b Replace the drier, Move the flush switch to the ICE position