A red Service Indicator LED is also included on the control board. This LED will either light continually or flash to indicate a service fault. A fault diagnosis chart in the service manual will help the technician determine the actual problem.

See chart next page.

Preventative maintenance for the IM is simple. Follow these steps to allow the unit to operate efficiently.

1.Clean the mesh air filter twice monthly to ensure good airflow.

2.Clean the condenser once a year using a brush or vacuum.

3.Check and clean the inlet water valve screen as needed to assure proper water flow.

4.Clean and sanitize the water distribution system annually using the recommended cleaner.

5.Wipe down the exterior using a soft cloth and neutral cleaner.

Cleaning tips:

A detailed cleaning label is located under the top cover. More detailed instructions are included in the customers Instruction Manual or in the product Service Manual.