5. ELECTRICAL CONNECTION

5. ELECTRICAL CONNECTION

WARNING

1.Electrical connection must be made in accordance with the instructions on a “WARNING” tag, provided with the pig tail leads in the Junction Box.

2.This icemaker requires a ground that meets the national and local electri- cal code requirements. To prevent possible electrical shock to individuals or extensive damage to the equipment, install a proper ground wire to the icemaker.

The white lead must be connected to the neutral conductor of the power source. Miswiring results in severe damage to the icemaker. See Fig. 3.

This icemaker must have a separate power supply or receptacle of proper capacity. See the Nameplate.

The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size conduit.

Usually an electrical permit and services of a licensed electrician are required.