[2]Remove the water from the potable water supply line:

1)Remove the Front Panel. (Except water-cooled models)

2)Move the Control Switch, on the Control Box, to the “OFF” position.

3)Wait 3 minutes.

4)Close the Potable Water Supply Line Shut-off Valve and open the Potable Water Supply Line Drain Valve. See Fig. 9.

5)Allow the line to drain by gravity.

6)Attach compressed air or carbon dioxide supply to the Potable Water Line Drain Valve.

7)Move the Control Switch to the “ICE” position.

8)Quickly blow the potable water line out using compressed air or carbon dioxide.

[3]Drain the Potable Water Tank:

1)Turn off the power supply.

2)Move the Control Switch, on the Control Box, to the “OFF” position.

3)Remove the Insulation Panel by removing thumbscrew, lifting up the panel slightly and pulling it toward you. Remove Cube Guide B by removing thumbscrew. Remove Cube Guide A. Remove Overflow Cap, Overflow Pipe, and Water Shield. See Fig. 11.

4)Remove the Drain Plug.

5)Remove all ice from the Storage Bin, and clean the Storage Bin.

6)Replace Drain Plug, Water Shield, Overflow Pipe, Overflow Cap, Cube Guide A, Cube Guide B, and Insulation Panel in their correct positions.

7)Replace the Front Panel in its correct position.

8)Close the Water Supply Line Shut-off Valve.