Hotpoint BS89EK, BS89EX Electrical Connection, 4 2 N L, The plug must be accessible at all times

Models: BS89EK BS89EX

1 12
Download 12 pages 61.27 Kb
Page 3
Image 3
Electrical Connection

Electrical Connection

Electrical connection

The electrical connection to the mains must be made on the appliance. The power voltage and frequency are as indicated on the rating plate.

!THIS APPLIANCE MUST BE EARTHED.

Connecting the power supply cable

To open the terminal board:

Using a screwdriver, press on the tabs situated on each side of the terminal board cover.

Pull open the terminal board cover.

To connect the power supply cable, proceed as follows:

_Unscrew the cable clamp screw and the contact screws L-N-$.

Fasten the wires beneath the screwheads using the following colour scheme: Blue (N) Brown (L) Yellow-Green￿ $

Fasten the power supply cable in the corresponding cable clamp and close the cover.

Power cable supply connection to the electrical

mains:GB

We recommend you use a power supply cable which is long enough to allow you to take the oven out of its recess in the event of maintenance operations (only use HAR - H 05 - RRF quality cables fitted with a plug conforming to the regulations in force.

The plug must be accessible at all times.

Unplug the appliance before all operations, even when replacing the oven lamp.

Using the appliance without correct earthing is highly dangerous.

!After connecting the appliance to the flexible cable, tighten all the screws on the terminal board.

TABLE OF CHARACTERISTICS

 

width 43.5 cm

Dimensions

height 32 cm

 

depth 40 cm

Volume

56 l

Electrical Connection:

4 2 N L

Voltage Frequency: 230 V-1+N 50Hz

Fuse Section: 16A Supply cable: 3x1.5mm2

Electrical

voltage: 220 - 240 V~ 50/60Hz

maximum power absorbed 2800 W

connections

(see data plate)

 

 

 

 

 

Directive 2002/40/EC on the label of

 

electric ovens. Standard EN 50304

ENERGY

Energy consumption for Natural

convection – heating mode:

LABEL

Traditional mode

 

Declared energy consumption for

 

Forced convection Class – heating

 

mode:

Baking

You can connect your oven to the system means of a terminal board. Refer to above information for the minimal cable sections and the calibration of the protective elements according to the connection.

If the appliance is installed with a junction box, an omnipolar circuit breaker - with a minimum contact opening of 3mm - should be installed between the appliance and the mains.

This appliance conforms to the following European Economic Community directives: 73/23/EEC dated 19/02/73 (Low Voltage) and subsequent amendments - 89/336/EEC dated 03/05/89 (Electromagnetic Compatibility) and subsequent amendments - 93/68/EEC dated 22/07/93 and subsequent amendments. 2002/96/EC

3

Page 3
Image 3
Hotpoint BS89EK, BS89EX manual Electrical Connection, 4 2 N L, The plug must be accessible at all times