Hotpoint CRO 742 DO B, CRO 642 D B operating instructions diagrams

Models: CRO 642 D B CRO 742 DO B

1 16
Download 16 pages 50.93 Kb
Page 4
Image 4
diagrams.

connection required and position the connection GB supports as shown in the following table and

diagrams.

4. Position the wires in accordance with the information given in the following table and diagrams and connect the appliance by tightening all the screws for the springs as much as possible.

Voltage and

Electrical connections

Terminal board

mains frequency

 

 

400V 3-N ~

 

Three-phase 400

50/60 Hz

 

 

 

 

 

 

5. Secure the power supply cable by fastening the cable clamp screw, then put the cover back on.

Phase

Phase

Phase

 

1

2

3

Three-phase 400

 

5

4

 

Earth Neutral

U-bolt

 

 

connection support

Connecting the electricity supply cable to the mains

If the appliance is being connected directly to the electricity mains an omnipolar switch must be installed with a minimum opening of 3 mm between contacts.

￿The installer must ensure that the correct electrical connection has been made and that it is fully compliant with safety regulations.

Before connecting the appliance to the power supply, make sure that:

The appliance is earthed and the plug is compliant with the law.

The socket can withstand the maximum power of the appliance, which is indicated on the data plate located on the appliance itself.

The voltage falls within the range of values indicated on the data plate.

The socket is compatible with the plug of the appliance. If the socket is incompatible with the plug, ask an authorised technician to replace it. Do not use extension cords or multiple sockets.

￿Once the appliance has been installed, the power supply cable and the electrical socket must be easily accessible.

￿The cable must not be bent or compressed.

￿The cable must be checked regularly and replaced by authorised technicians only.

￿The manufacturer declines any liability should these safety measures not be observed.

￿Do not remove or replace the power supply cable for any reason. Its removal or replacement will void the warranty and the CE marking. INDESIT does not assume liability for accidents or damage arising from replacement/removal of the original power supply cable. Replacement can only be accepted when carried out by personnel authorised by INDESIT and using an original spare part.

4