START-UP AND OPERATION

Raise the Curved Glass

To raise the front curved glass, grab the lift handle extrusion on the bottom edge of the front curved glass and lift up.

Gas cylinders hold the glass open for hands free access to the interior of the case.

Merchandiser Start-Up

Front Curved Glass

Lift Handle

Coil Fan

Deck Pan

Register

Turn on the main power. Switch is on the control panel at the rear left hand side of base. Supply power will start evaporator coil fan(s), the front fan and the evaporator/ condensate pan. It will supply power to the light switch and thermostat, (self-contained units).

From the front of the case, raise the deck pans and check to see that the coil fans are all functioning properly.

On the top of the front panel a register di- rects air flow provided by the front fans, (front air flow is to prevent condensation from forming on the curved glass). Check across the top of the front panel to see if air is discharging across the entire front of the case.

Turn on the lights. Light switch is in the rear control panel. First time lighting may require a short warm up period for the bulbs. Slightly dim or a flickering of new bulbs is normal. If lights do not turn on, check all of the race- way plugs. The lighting is wired in series so all lights must be plugged in or recepta- cles capped in order for the case to light.

Front Fan

Lights

Main Power

Condenser Warning Light

Thermostat

R

888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com