Hotpoint SCL 08 EB operating instructions Electrical connection, Fitting the power supply cable

Models: SCL 08 EB

1 12
Download 12 pages 44.55 Kb
Page 5
Image 5
Electrical connection

Electrical connection

Ovens equipped with a three-pole power supply cable are designed to operate with alternating current at the voltage and frequency indicated on the data plate located on the appliance (see below).

Fitting the power supply cable

• The socket is compatible with the plug of the appliance.

If the socket is incompatible with the plug, ask an GB authorised technician to replace it. Do not use extension cords or multiple sockets.

! Once the appliance has been installed, the power supply

cable and the electrical socket must be easily accessible.

L

N

1.Open the terminal board by inserting a screwdriver into the side tabs of the cover. Use the screwdriver as a lever by pushing it down to open the cover (see diagram).

2.Install the power supply cable by loosening the cable clamp screw and the three wire contact screws

L-N-Fitting the power supply cable.

Connect the wires to the corresponding terminals: the Blue wire to the terminal marked (N), the Brown wire to the terminal marked (L) and the Yellow/Green wire

to the terminal marked safety measures not be observed. (see diagram).

! The cable must not be bent or compressed.

! The cable must be checked regularly and replaced by

authorised technicians only (see Assistance).

! The manufacturer declines any liability should these

safety measures not be observed.

APPLIANCE SPECIFICATIONS

Dimensions*

width 43.5 cm

height 32,4 cm

 

depth 41.5 cm

 

 

Volume*

59 l

 

 

Dimensions**

width 45.5 cm

height 32,4 cm

 

depth 41.5 cm

 

 

Volume**

62 l

 

 

Electrical

voltage: 230 - 240 V~ 50/60 Hz

(see data plate)

connections

maximum power absorbed

3.Secure the cable by fastening the clamp screw.

4.Close the cover of the terminal board.

Connecting the supply cable to the mains

Install a standardised plug corresponding to the load indicated on the data plate (see table).

The appliance must be directly connected to the mains using an omnipolar switch with a minimum contact opening of 3

mminstalled between the appliance and the mains. The switch must be suitable for the charge indicated and must comply with current electrical regulations (the earthing wire must not be interrupted by the switch). The supply cable must be positioned so that it does not come into contact with temperatures higher than 50°C at any point (the back panel of the oven, for example).

!The installer must ensure that the correct electrical connection has been performed and that it is fully compliant with safety regulations.

Before connecting the appliance to the power supply, make sure that

The appliance is earthed and the plug is compliant with the law.

The socket can withstand the maximum power of the appliance, which is indicated on the data plate.

The voltage is in the range between the values indicated on the data plate.

 

2800-3000 W

 

 

 

Directive 2002/40/EC on the label

 

of electric ovens. Standard EN 50304

ENERGY

Energy consumption for Natural

LABEL

convection - heating mode:

 

Convection mode

 

Declared energy consumption for

 

Forced convection Class - heating

 

mode:

 

Baking

This appliance conforms to the following European Economic Community directives:

-2006/95/EEC of 12/12/06 (Low Voltage) and subsequent

amendments;

- 2004/108/EEC of 15/12/04 (Electromagnetic Compatibility) and subsequent amendments;

- 93/68/EEC of 22/07/93 and subsequent amendments.

-2002/96/EC and subsequent amendments.

*Only for models with drawn rails.

**Only for models with wire rails.

PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24

5

Page 5
Image 5
Hotpoint SCL 08 EB Electrical connection, Fitting the power supply cable, safety measures not be observed