Technical Data

Technical Data

Introduction

Data badge

Lower part of front frame and rear of appliance.

Pressure setting

 

Cat I2H (GB/IE)

G20 @ 20mbar

Gas category

 

I2H

 

Appliance class

 

Class 3

 

Ignition

Mains operated re-ignition generator

Oven light 25W

Electrical supply

220 - 240V ~ 50Hz, 44W

Grill

 

Nominal Rate Qn

2.4kW

Injector

1.12mm

Spark gap

3 - 4mm

Oven

Bray type burner, sheet steel body, stainless steel flame strip

Nominal Rate Qn

2.5kW

Injector

1.25mm

Spark gap

3 - 4mm

Thermostat bypass

50

Oven injector - If the injector is removed or replaced for any reason, it is mandatory to apply Hylomar PL32 or Plasticol X10 sparingly to the thread prior to (re) fitting.

Maximum heat input

Qn 2.5kW

Countries of destination GB - Great Britain, IE - Ireland

The cooling fan

The cooling fan helps to keep the exterior cool during normal use. When a burner is operated, you should hear the cooling fan switch on automatically and be able to feel air evacuating from the appliance vents just below the fascia. The cooling fan will continue to operate for approximately 10 minutes after turning off the burners. This is normal.

If there is no such indication that the fan is operating, the appliance will require servicing. DO NOT USE THE APPLIANCE UNTIL IT HAS BEEN SERVICED. Switch the appliance off at the mains and contact Customer Support.

For your safety

This appliance has a built in safety device to isolate the gas and electric supplies to various components in the event of fan failure.

If the minute minder and lights do not function, and the ignition system stops working, the safety device has operated. Within an hour the safety device will reset itself and the minute minder display will flash.

To reset the minute minder, simply press the reset button and set the time of day within 5 seconds by pressing the “+” plus and “-” minus buttons.

If when a burner control is turned on, the fan does not operate in the normal way, then the appliance will require

servicing. DO NOT USE THE APPLIANCE UNTIL IT HAS BEEN SERVICED. Switch the appliance off at the mains and contact Customer Support.

Continued use of the appliance without it being serviced could result in

excessive temperatures being generated, which in turn could reduce the life of certain components.

Ventilation

The use of a gas cooking appliance results in the production of heat and moisture in the room in which it is installed. Ensure that the kitchen is well ventilated; keep natural ventilation holes open or install a mechanical ventilation device (mechanical ventilator).

Prolonged intensive use of the appliance may call for additional ventilation, for example opening a window, or more effective ventilation, for example increasing the level of mechanical ventilation where present.

This appliance is not connected to a combustion products evacuation device. It must be installed and connected in accordance with current installation regulations. Particular attention must be given to the relevant regulations regarding ventilation.