Removal and replacement procedures
c.Remove the display panel from the display enclosure.
d.Remove the six Phillips PM2.0×3.0 screws 1 that secure the display hinges to the display panel.
e.Remove the display hinges 2 from the display panel. The display hinges are available using spare part number
5.If it is necessary to replace the webcam module cable, release the webcam module cable 1 from the clips and routing channels 2 built into the display enclosure, and then remove the cable 3. The webcam module cable is included in the Display Cable Kit, spare part number
Reverse this procedure to reassemble and install the display assembly.
Maintenance and Service Guide |