HP 800 Value, Effect, descriptor, Horizontal Motion Index, Number of 1/120 inch, increments, 0 to

Models: 700

1 124
Download 124 pages 26.67 Kb
Page 42
Image 42
10.8.5Horizontal Motion Index

HP PCL Commands

10.8.5Horizontal Motion Index

TABLE 21.

 

 

 

 

 

Horizontal Motion Index (HMI) - Esc & k # H

 

Value

 

DJ600

DJ610C

DJ660C

DJ670C

DJ680C

DJ690C

DJ695C

DJ810C

DJ830C

DJ850C

DJ870C

DJ880C

DJ890C

DJ895C

DJ970C

HP2000C

 

 

EFFECT

#

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

n

 

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

 

 

Number of 1/120 inch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

increments

Default

 

Determined by the pitch or height (x 112%) value in the default font

 

 

 

 

 

 

descriptor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Range

 

0 to 126.99

- Command is ignored for out of range values

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Designates the width of columns used for horizontal movement calculations. In the vertical text path direction, designates the height of rows used for inter-character movement calculations.

HMI defaults to the invoked font’s space character when any of the font’s characteristics (ori- entation, character set, pitch, etc.) are changed, when switching between primary and second- ary fonts with <SI> and <SO>.

For fixed pitch fonts, HMI affects all printable characters, including the space and backspace characters. For proportionally spaced fonts, HMI may affect only the space character: if the space character glyph exists, CAP moves the width of the space character; otherwise CAP moves according to the HMI.

For multiple fixed-pitch fonts, the HMI directly affects the nominal (full width) space of the font. Other spacings are scaled linearly according to the current HMI value, i.e., the character widths are multiplied by the ratio of the HMI to the nominal width.

In the vertical text path direction mode, the HMI defaults to the height (x 112%) of the font. In fixed-pitched or multiple-fixed-pitched fonts, the HMI takes on the height (x 112%) of the fixed- pitch font.

For proportionally-spaced fonts, the HMI may affect only the space character. If the space character glyph exists, CAP moves the height (x 112%) of the space character. Otherwise the CAP moves according to the HMI.

42

HP DeskJet 600, 700, 800, 900 & HP 2000 Series PCL Developer’s Guide

Page 42
Image 42
HP 800, 700 manual Value, Effect, descriptor, Horizontal Motion Index, Number of 1/120 inch, increments, 0 to