Table B-1. Power supply placement

Figure B-2. HP BladeSystem c3000 Enclosure – Power supply population guidelines

Table B-1. Power supply placement

Number of power supplies

Power supply bays used

 

 

2

1 and 4

 

 

4

1, 2, 4, and 5

 

 

6

All power supply bays filled

 

Table B-2. Power supply redundancy options

 

 

Number of power supplies

Power supply bays used

 

 

1+1

1 and 4

 

 

2+1

1, 4, and 2

 

 

3+1

1, 4, 2, and 5

 

 

4+1

1, 4, 2, 5, and 3

 

 

5+1

Populate all power supply bays

 

 

Table B-3. AC redundancy options

 

 

 

Number of power supplies

Power supply bays used

 

 

1+1

1 and 4

 

 

2+2

1, 2, 4, and 5

 

 

3+3

Populate all power supply bays

 

 