HP BladeSystem Enclosure technologies manual Recommendations, Summary

Models: BladeSystem Enclosure technologies

1 28
Download 28 pages 41.5 Kb
Page 21
Image 21
Recommendations

The enclosure link-down port connects to the enclosure link-up port on the enclosure below it. The enclosure link-up port connects to the enclosure link-down port on the enclosure above it. Linking the enclosures enables the rack technician to access all the enclosures through the open link-up/service port. If more c-Class enclosures are added to the rack, they can be linked through the open enclosure link-up port on the top enclosure or the link-down port on the bottom enclosure.

NOTE

The enclosure link ports are designed only to support c-Class enclosures in the same rack. The enclosure link-down port on the top enclosure is the service port. The enclosure link-down port on the bottom linked enclosure is unused.

IMPORTANT

The HP BladeSystem c-Class enclosure link ports are not compatible with the HP BladeSystem p-Class enclosure link ports.

Recommendations

HP recommends the following for configuring BladeSystem c-Class enclosures:

Use Virtual Connect or managed switches to reduce cabling and management overhead.

Use the HP BladeSystem Power Sizer.

For all server blades other than BL685c, the InfiniBand 4x DDR single-port mezzanine card will work in Mezzanine 1, but it will work better in Mezzanine 2 or Mezzanine 3. For BL685c, the InfiniBand 4x DDR single-port mezzanine card will work equally well in Mezzanine 1, Mezzanine 2, or Mezzanine 3 connectors.

The HP BladeSystem c-Class Solution Overview might indicate to install the Onboard Administrator into the rear of the enclosure. This information applies to only the HP BladeSystem c7000 Enclosure. Install the Onboard Administrator module into the front of the HP BladeSystem c3000 Enclosure.

Summary

The HP BladeSystem c3000 Enclosure is the next generation of a new modular computing architecture that consolidates and simplifies infrastructure, reduces operational cost, and delivers IT services more effectively. The c3000 Enclosure is designed for remote sites, small and medium-sized businesses, and data centers with special power and cooling constraints. Thermal Logic technologies provide the mechanical design features, built-in intelligence, and control capabilities throughout the BladeSystem c-Class that enable IT administrators to make the most of the power and thermal environments. The shared, high-speed midplane and pooled-power backplane in the enclosure accommodate new bandwidths and new technologies. The Onboard Administrator supplies an intelligent infrastructure to provide essential power and cooling information and help automate the management of the infrastructure. The BladeSystem c3000 Enclosure provides all the power, cooling, and infrastructure to support c-Class modular servers, interconnects, and storage components, today and throughout the next several years.

21

Page 21
Image 21
HP BladeSystem Enclosure technologies manual Recommendations, Summary