The following table lists common Event Log error messages, along with suggested solutions.
Message | Suggested solution | |
|
| |
Error: ioDrive(x) | To update the firmware, see "Upgrading the device firmware using Windows (on page | |
firmware is too | ||
old. The firmware |
|
|
must be updated. |
|
|
Error: The | 1 | Reinstall the Windows driver. |
ioDrive(x) | 2 | Remove and reseat the IO Accelerator device. |
initialization | 3 | Remove the IO Accelerator and insert it in a different slot. |
failed with error |
|
|
code 0xerrorcode |
|
|
(where errorcode is a |
|
|
number which might |
|
|
vary) |
|
|
|
| |
Error: The | This error might appear after an unmanaged shutdown. You can use either the | |
ioDrive(x) was not | ||
attached. Use the | This attach process might take up to ten minutes as the utility performs a consistency | |
check on the drives. | ||
utility to rebuild |
|
|
the drive. |
|
|
Warning: The | The IO Accelerator must attach to the Windows operating system to be available to | |
ioDrive(x) was not | users and applications. This attach normally occurs at boot time. As part of this attach | |
attached because | process, the IO Accelerator driver verifies the presence of an AutoAttach parameter | |
in the Windows® registry. If you create this Registry parameter to disable | ||
disabled. | the attach operation does not complete. | |
| To attach an unattached IO Accelerator: | |
| 1 | Run the HP IO Accelerator Management Tool. |
| 2 | Select your unattached IO Accelerator from the Device Tree. |
| 3 | Click Attach. |
| 4 | Confirm the Attach operation. |
| Your IO Accelerator now attaches to the Windows® operating system. To | |
| auto attach at boot time, see "Enabling auto attach ("Enabling Autoattach" on page | |
| ||
|
|
|
Windows Server environments 36