NOTE: MSI was disabled to obtain these statistics.
Required operating environment
The IO Accelerator is supported for use in the following operating environments:
•Windows Server 2003
•Windows Server 2008
•Windows Server 2008
•Windows Server 2012
IMPORTANT: All operating systems must be
NOTE: IO Accelerators cannot be used as hibernation devices.
Supported firmware revisions
After February 19, 2013, all IO Accelerators ship with firmware version 7.1.13.109322 or higher. This firmware version only works with VSL 3.2.2 or higher. If you are installing a recently purchased or a replacement IO Accelerator into a system that already has IO Accelerators installed, then you must upgrade the firmware on the previously installed devices to 7.1.13.109322 or higher. You must also upgrade the VSL to 3.2.2 or higher. Upgrading the firmware and VSL on cards that were running firmware versions 6.x.x or higher and VSL 3.x.x or higher is NOT data destructive. However, HP recommends that you back up any data on the device before performing the upgrade. The latest supported version of the firmware and VSL can be found on the HP website (http://www.hp.com).
Release | Firmware revision |
|
|
1.2.4 | 17350 |
1.2.7 | 36867 or 42014 |
1.2.8.4 | 43246 |
2.2.x | 43674 |
2.2.3 | 101583 |
2.3.1 | 101971 4 or 101971_6 |
3.1.1 | 107004 or greater |
3.2.3 | 109322 |
Supported hardware
HP IO Accelerator for BladeSystem
BladeSystem
Introduction 9