Combi HP thermostatic mixer shower
washer. |
| |
Make sure the inlet elbows are positioned the |
| |
correct way. Offer the valve up to the mounting |
| |
bracket and secure using the screws provided |
| |
(fig.42). |
| |
Complete the pipework to the shower marking |
| |
off the length to enter the elbows. Remove the |
| |
valve and cut the pipes to length. |
| |
Flush pipework to clear the system of all |
| |
debris and check for leaks. |
| |
Important: The inlet elbows contain check |
| |
valves that may be damaged if debris is not |
| |
flushed through prior to fitting. |
| |
Where this is not possible refer to the ‘flushing | T00260 | |
procedure’ on page 20. | ||
| ||
Refit the valve to the mounting bracket and |
| |
pipework. Tighten the inlet nuts and inlet elbow |
| |
grub screws. |
| |
If fitting a fixed head, refer to the ‘Fitting the |
| |
fixed head’ section and complete the outlet |
| |
pipework to the fixed head position. |
| |
Note: The outlet pipe for the fixed head should |
| |
protrude from the surface of the wall between |
| |
50 mm and 65 mm. Before fitting the fixed head |
| |
to the wall, connect a hose to the pipework and |
| |
direct to waste. |
| |
If fitting a riser rail kit refer to ‘Fitting the |
| |
bulkhead’ and complete the outlet pipework. |
| |
Before fitting the bulkhead to the wall, connect |
| |
the shower hose and direct it to waste. | T00261 | |
Open the isolating valves to the shower and |
| |
flush through. Make sure the flow control |
| |
is opened fully and the temperature control |
| |
is rotated to ‘Hot’ and then to ‘Cold’ (if |
| |
necessary depress the maximum temperature |
| |
override button). Check for leaks and remedy if |
| |
necessary. |
| |
Make good the wall surface and make sure |
| |
the plastering/sealing is taken tight to the pvc |
| |
shroud (fig.43). Should the shroud protrude |
| |
beyond the wall surface, trim flush with a sharp |
| |
knife (fig.34). |
| |
Offer the flush mount plate up to the finished |
| |
surface. Make sure the valve and the plate are |
| |
aligned and mark the ‘arrowed’ fixing holes |
| |
(fig.35). Remove the flush mount plate then | T00262 |
Fig.40
Fig.41
Fig.42
17