Combi HP thermostatic mixer shower

packages with a cold take off after the pressure reducing valve to the cylinder.

The layout and sizing of pipework must be such that nominally equal inlet supply pressures are achieved and the effects of other draw-offs are minimised.

d)Mains pressurised thermal store

(fig.5)

Packages of this type, fitted with a tempering valve (blender valve) can be used. A drop tight pressure reducing valve must be fitted if the supply pressures exceed 5 bar maintained.

Fig.4 diagrammatic view (not to scale)

Mixer shower

Safety devices

not shown

Service valves

An expansion vessel (shown in fig.5) must be fitted, and regularly maintained, to make sure the unit is not damaged by excess pressures. This may already be installed externally or internally within the thermal store (check with thermal store manufacturer).

The layout and sizing of pipework must be such that nominally equal inlet supply pressures are achieved and the effects of other draw-offs are minimised.

Unvented hot water storage unit

Pressure

reducing valveExpansion vessel

Pressure

Balanced cold

reducing valve

mains supply

Cold mains supply

Stop tap

T00223

Fig.5 diagrammatic view (not to scale)

Mixer valve

Service

valves

Hot Blender water valve

Expansion

 

vessel

 

Pressure

 

reducing valve

Return Flow

Stop tap

Boiler

 

Cold mains supply

T00224