2.Remove the service cover release latch actuator from the base enclosure.

3.Turn the base enclosure right side up, with the front toward you.

4.Remove the service cover release latch arm spring from the spring retention hooks on the service cover release latch arm (1) and the base enclosure (2).

5.Slide the service cover release latch arm (1) as far to the left as it will go.

6.Flex the middle of the service cover release latch arm (2) up and back until it releases from the track built into the base enclosure.

Component replacement procedures

49