Fuser pressure plate
1Remove all covers, the RFI shield, the printer door, the exit roller, and the delivery assembly.
2Remove the two (2) screws (callout 1).
3Press the fuser plate retainer clips out (callout 2) to release the pressure plate.
4Rotate the plate around and toward the back (callout 3) and lift up to remove it.
2
3
1
Figure 42. Fuser pressure plate removal