Trigger Hold Multiple Mode

Figure 2-2Trigger Single Mode

Trigger Hold Multiple Mode

When the trigger is pulled, scanning starts and the product scans until the trigger is released or a programmable duration has elapsed. Reading a label does not disable scanning. Double Read Timeout prevents undesired multiple reads while in this mode.

Trigger Pulse Multiple ModeFlashing ModeManual backgroundManual background NOTE: See the Programming Guide (PG) for additional programmable features. In this case: Scanning Active Time.

Double Read Timeout is also programmed using the PG.

Figure 2-3Trigger Hold Multiple Mode

Trigger Pulse Multiple Mode

When the trigger is pulled and released, scanning is activated until programmable duration has elapsed or the trigger has been pulled again to transition to another state. Double Read Timeout prevents undesired multiple reads while in this mode.

Manual backgroundManual backgroundManual backgroundManual background NOTE: See the Programming Guide (PG) for additional programmable features. In this case: Scanning Active Time.

Double Read Timeout is also programmed using the PG.

Figure 2-4Trigger Pulse Multiple Mode

Flashing Mode

The reader flashes on and off regardless of the trigger status.

Manual backgroundManual backgroundManual backgroundManual background NOTE: This is controlled by Flash On Time and Flash Off Time. Use the PG to program these options.

4 Chapter 2 Using the Scanner

ENWW