Disabling browser access to Desktop Intelligence
Desktop Intelligence is not installed with SRM Report Optimizer, so references to that feature should be removed from the user interface. To remove these references by disabling browser access to Desktop Intelligence:
1.Launch the Central Management Console as described in ”Accessing the Central Management Console” on page 4.
1.In the Manage section on the home page, click BusinessObjects Enterprise Applications.
2.Click Desktop Intelligence.
3.On the Administrators row, click Advanced in the Net Access column.
4.Select Explicitly Denied for all of the available choices, and click OK.
5.On the Everyone row, click Advanced in the Net Access column.
6.Select Explicitly Denied for all of the available choices, and click OK.
Adding the Report Designers group
Add the Report Designers group to allow easy addition and modification of rights for users who will have report creation, modification, and deletion rights. To add the Report Designers group:
1.Launch the Central Management Console as described in ”Accessing the Central Management Console” on page 4.
2.Click Groups in the Organize section.
3.Click New Group.
4.Enter Report Designers in the Group Name box.
5.Add the following text to the description:
Report Designers group. Users added to this group will have the rights and privileges to create, modify, and delete new and existing reports.'
6.Click OK.
7.Click the Member of tab.
8.Click the Member of button.
9.Select Administrators and click the > button.
10.Click OK.
11.Click the Rights tab.
12.In the Access Level
13.Click Update.
Assigning report designing privileges to report designers
The Report Designers group needs to be assigned the appropriate application rights. To assign the appropriate rights:
1.Launch the Central Management Console as described in ”Accessing the Central Management Console” on page 4.
User Guide | 7 |