Replaceable Parts/Accessories

Refer to the disassembly diagram on page 6-5.

Call outDescriptionHP Part Number

 

 

 

F1

Fuse, 500 mA, 250 V fast blow Littlefuse 216-500

2110-0940

DO NOT SUBSTITUTE

 

 

 

 

 

F2

Fuse, 15 A, 600 V fast blow Littlefuse KLK15

2110-0941

DO NOT SUBSTITUTE

 

 

 

 

 

MP1

Top case assembly

00974-64401

 

 

 

MP2

Dust/moisture seal

00971-64403

 

 

 

MP3

Bottom case assembly (includes stand)

00974-64402

 

 

 

 

Rubber Boot

00971-86001

 

 

 

 

Replacement Test Leads, 2 pair

E2305A

 

 

 

 

Temperature probe, 5 KΩ Thermistor

E2308A

 

 

 

 

Surface temperature sensor,

 

 

Thermistor ±0.1°C

40653B

 

12" lead, requires dual banana plug

 

 

 

 

 

Soft Case

E2304A

 

(fits meter with rubber boot)

 

 

 

 

 

 

 

 

Operator protection from electric shock hazard is provided by a double insulated enclosure. Refer to the Safety Summary for maximum voltage specifications. When servicing, use only specified replacement parts.