User interface

Virtual Connect Manager allows users to change the number of VC-FC Module uplink ports connected to an external Fabric Switch without a warning while a server might be accessing remote storage devices.

Virtual Connect Manager shows either a server blade or an interconnect module as degraded (but not both) for an I/O Ekey mismatch.

If non-Administrator credentials are entered for the Onboard Administrator during Virtual Connect Domain Import, the import fails without explanation. The VC-Enet module must be power cycled to recover and allow for entry of new OA credentials.

Network uplinks that are linked after the Network Setup Wizard has been started may not show proper link status in the wizard. When the wizard is completed, all uplink link statuses are displayed correctly.

The main window of the GUI might show more updated information than the left window. Refresh the page to synchronize.

A server profile can be assigned to a device bay with a server that has fewer physical NIC ports than defined in the server profile. In most cases, a warning is provided, but in some cases it is not.

If a server is rebooted several times while its server profile is being edited, an error displaying an XSL transformation failure may be displayed. Do not edit a server profile while repeatedly rebooting a server.

In the Bay Summary screen for a VC-FC module in Virtual Connect Manager, some servers might be displayed with the incorrect model number. The model number is displayed correctly in other screens and in the Onboard Administrator.

When using Internet Explorer 6 or Internet Explorer 7, some web pages do not display correctly on machines configured for Chinese language options. Change the language encoding in Internet Explorer to "Western European (ISO)" or use Mozilla Firefox.

In the Server Connections tab of the Ethernet Networks screen, the port status shows OK even if the server port is not linked.

Firmware update

The VC-Enet module firmware must be updated before the VC-FC module firmware. Otherwise, the VC-FC firmware might not appear to be successfully updated.

If the firmware update procedure indicates a failure to activate a module or appears to be stuck, it might be caused by a timeout and/or a stale web page. To refresh the screen and verify the actual update status, click the Firmware update link under Domain Settings in the left navigation pane of the VCM user interface.

During the firmware update activation countdown, an Internet Explorer pop-up might be displayed stating "Failed to create processor object: The stylesheet does not contain a document element. The stylesheet may be empty, or it may not be a well-formed XML document." This pop-up can be dismissed without consequences.

Known issues 11