Event, Error and Warning Messages

Events Without Sensors

￿￿￿￿E%#￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿2￿￿￿￿￿￿￿￿￿￿￿￿￿3￿￿￿￿￿O￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿*"@￿￿￿￿￿￿￿

TripletEventdata2data3Notes

 

 

 

 

 

10:70:64SEL almost full

1F

%fullThe BMC logs this when the SEL is

 

 

 

 

75% full

 

 

 

 

 

12:70:04BMC entering firmware

 

 

 

 

update mode

 

 

 

 

 

 

 

 

12:70:05SFW flash lnlock

 

 

System firmware update in

 

 

 

 

progress

 

 

 

 

 

12:70:06Front panel lock

 

 

Disables all power and reset

 

 

 

 

requests from ipmi or sensors

 

 

 

 

 

12:F0:06Front panel unlock

 

 

 

 

 

 

 

 

12:70:07Firmware update app:

 

 

 

 

starting component cpdate

 

 

 

 

 

 

 

 

12:F0:07

Firmware update app:

 

 

 

 

ending comionent update

 

 

 

 

 

 

 

 

12:70:80BMC entering specialMode

Mode is a bit-map:

 

mode

 

 

Bit 0: Shmoo

 

 

 

 

Bit 1: MfgTest

 

 

 

 

Bit 2: Shutdown override

 

 

 

 

Bit 3: Fixed fan speed

 

 

 

 

Bit 4: Mfg

 

 

 

 

Bits 7-5: unused, set to 0

 

 

 

 

 

12:70:A1BMC firmware initializingMajor FWMinor

 

 

 

revFW rev

 

 

 

 

 

 

1D:70:00BMC cold reset

 

 

 

 

 

 

 

 

1D:70:01BMC warm reset

 

 

 

 

 

 

 

 

1D:70:02BMC cold reset after SDRR

 

 

 

 

update

 

 

 

 

 

 

 

 