Band

Typical

Unit

PCL

Configuration

 

 

 

value

 

 

 

 

 

 

81

mA

10

1 Up/1 Down

 

 

 

 

 

 

 

 

 

 

123

 

 

2 Up/1 Down

 

 

 

 

 

 

 

 

The typical values are the average of some test samples.

5.6 Reliability Features

Table 5-8lists the test conditions and results of the mechanical reliability of the

MG323 module.

Table 5-8Test conditions and results of the mechanical reliability of the MG323 module

Item

Test Condition

Standard

 

 

 

Low-temperature

Temperature: –40ºC±2ºC

IEC60068

storage

Test duration: 24 h

 

 

 

 

 

 

High-temperature

Temperature: 85ºC±2ºC

IEC60068

storage

Test duration: 24 h

 

 

 

 

 

 

Low-temperature

Temperature: –30ºC±2ºC

IEC60068

working

Test duration: 24 h

 

 

 

 

 

 

High-temperature

Temperature: 75ºC±2ºC

IEC60068

working

Test duration: 24 h

 

 

 

 

 

 

Damp heat cycling

High temperature: 55ºC±2ºC

IEC60068

 

Low temperature: 25ºC ±2ºC

 

 

Humidity: 95%

 

 

Repetition times: 4

 

 

Test duration: 12 h+12 h

 

 

 

 

Temperature shock

Low temperature: –40ºC±2ºC

IEC60068

 

High temperature: 85ºC±2ºC

 

 

Temperature change interval: < 30s

 

 

Test duration: 15 min

 

 

Repetition times: 100

 

 

 

 

Issue 06 (2013-06-13)