HUAWEI MG323 GSM M2M Module

 

 

Hardware Guide

Electrical and Reliability Features

 

 

 

 

 

 

Item

Test Condition

Standard

 

 

 

 

 

 

 

Condensation test

Temperature: –40º ±2°C

IEC60068

 

 

 

Time for keeping condensed: 2 h

 

 

 

 

Recovery temperature: 25ºC±2°C

 

 

 

 

Recovery time: 5 min

 

 

 

 

Repetition times: 6

 

 

 

 

 

 

 

 

Dust test

Dust density: 2 kg/m3

IEC60068

 

 

 

Dust type: dry talcum powder

 

 

 

 

Size requirement: < 75 µm

 

 

 

 

Duration: 8 h

 

 

 

 

 

 

 

 

Salty fog test

Temperature: 35°C

IEC60068

 

 

 

Density of the NaCl solution: 5±1%

 

 

 

 

Spraying interval: 8 h

 

 

 

 

Duration of exposing the module to

 

 

 

 

the temperature of 35°C: 16 h

 

 

 

 

 

 

 

 

Sun exposure

Radiation strength: 1120 W/m2

IEC60068

 

 

 

Duration: 20 h

 

 

 

 

Repetition time: 3

 

 

 

 

 

 

 

 

Sine vibration

Frequency range: 5 Hz to 200 Hz

IEC60068

 

 

 

Acceleration: 10 m/s2

 

 

 

 

Frequency scan rate: 1 oct/min

 

 

 

 

Test period: 3 axial directions. Five

 

 

 

 

circles for each axial direction.

 

 

 

 

 

 

 

 

Shock test

Half-sine wave shock

IEC60068

 

 

 

Peak acceleration: 300 m/s2

 

 

 

 

Shock duration: 11 ms

 

 

 

 

Test period: 6 axial directions. One

 

 

 

 

shock for each axial direction.

 

 

 

 

 

 

 

 

Clash test

Half-sine wave

IEC60068

 

 

 

Peak acceleration: 180 m/s2

 

 

 

 

Pulse duration: 6 ms

 

 

 

 

Repetition time: 6 directions. 1000

 

 

 

 

times for each direction.

 

 

 

 

 

 

 

Issue 06 (2013-06-13)

Huawei Proprietary and Confidential

43

Copyright © Huawei Technologies Co., Ltd.

 

 

Page 43
Image 43
Huawei MG323 manual Test Condition Standard