Huawei MG323 ESD Features, ESD Test Standard, Contact Discharge, Air Discharge, Test Condition

Models: MG323

1 54
Download 54 pages 46.29 Kb
Page 44
Image 44
5.7 ESD Features

HUAWEI MG323 GSM M2M Module

 

 

Hardware Guide

Electrical and Reliability Features

 

 

 

 

 

 

Item

Test Condition

Standard

 

 

 

 

 

 

 

Drop test

First case: 0.3 m in height. Drop the

IEC60068

 

 

 

MG323 module on the marble

 

 

 

 

terrace with one surface facing

 

 

 

 

downwards twice. Six surfaces

 

 

 

 

should be tested.

 

 

 

 

Second case: 0.8 m in height. Drop

 

 

 

 

the MG323 module on the marble

 

 

 

 

terrace with one surface facing

 

 

 

 

downwards twice. Six surfaces

 

 

 

 

should be tested.

 

 

 

 

 

 

 

5.7 ESD Features

Pay great attention to ESD protection when using the MG323 module. To ensure that the working reference GND is connected to the MG323 module and user interface board properly, you are recommended not to spray a coated insulation on the structure fixing hole (connecting with the main reference GND of the user interface board) and connect the hole with the MG323 module through the metal fastener or other low-resistance fastener. For specific installation method and fastener specification, see “6.4 MG323 Module Installation Description."

Table 5-9lists the test results of the ESD performance of the MG323 module according to the EN61000-4-2 standard.

Table 5-9ESD performance

ESD Test Standard

Contact Discharge

Air Discharge

 

 

 

EN61000-4-2

±4 kV

±8 kV

 

 

 

Issue 06 (2013-06-13)

Huawei Proprietary and Confidential

44

Copyright © Huawei Technologies Co., Ltd.

 

 

Page 44
Image 44
Huawei MG323 manual ESD Features, ESD Test Standard, Contact Discharge, Air Discharge, Test Condition