Switch and Jumper Settings
Overview
Several switch and jumper settings are required for proper operation of the VNA Card. The following settings are set during the system commissioning and programming and should not be changed. If replacing an existing
FrontPanelDIPSwitch(SW5)Settings
NOTE: The front panel DIP switches (SW5) can be updated without powering down the card rack and without resetting the MCU.
Position Number
Name
Top | 1 | Line Build 0 (LB0) |
|
|
|
| 2 | Line Build 1 (LB1) |
|
|
|
| 3 | Line Build 2 (LB2) |
|
|
|
| 4 | Receive Equalizer Gain Limit |
|
|
|
| 5 | Lamp Test |
|
|
|
| 6 | Customer Disconnect Enable |
|
|
|
| 7 | Local Loop Back |
|
|
|
Bottom | 8 | Remote Loop Back |
|
|
|
The Line Build # switches control the “line build” (signal’s amplitude) of the T1 transmit line. Set the Line Build # switches according to the following table:
LB0 | LB1 | LB2 | T1 Line Length | |
|
|
|
| |
|
|
|
| |
Open | Open | Open | ||
|
|
|
|
|
Open | Open | Closed | (133 to 266 feet) | |
|
|
|
|
|
Open | Closed | Open | (266 to 399 feet) | |
|
|
|
|
|
Open | Closed | Closed | (399 to 533 feet) | |
|
|
|
|
|
Closed | Open | Open | (533 to 655+ feet) | |
|
|
|
| |
Closed | Open | Closed | ||
|
|
|
| |
Closed | Closed | Open | ||
|
|
|
| |
Closed | Closed | Closed | ||
|
|
|
|
|
\\s_eng\gtcproddocs\standard ioms - current release\42004 instr.