SINGLE PHASE HEATING ELEMENT

SINGLE PHASE HEATING ELEMENT

1.Disconnect power from unit.

2.Shut off incoming water supply.

3.Attach hose to drain connection.

4.Lift manual release lever on relief valve to let air into system or break union on outgoing water line.

5.Drain water from tank.

6.Disconnect the wires from the heating element terminals.

Tank Flange

Wires Manual background

7. Remove the 3/8-16 nuts.

8. Withdraw element assembly and remove gasket.

Gasket

Element Assembly

NutsManual background

9. Install new gasket and insert new heating element.

10.Rewire element according to type of unit as shown in your drawing.

11.Fill tank and check around gasket for any leaks.