2 • Installing the Ceiling Plate

Manual background CAUTION: To avoid possible electrical shock, before installing your fan, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a tag, to the service panel.

2-1. Drill two pilot holes into the wood support structure through the outermost holes in the outlet box. e pilot holes should be 9/64” in diameter.

2-2. Align the slotted holes in the ceiling plate with the pilot holes you drilled in the wood support structure. For proper alignment use slotted holes directly across from each other.

2-3. Place the ceiling gasket over the hanger bracket so that the slots and the raised surfaces on the ceiling gasket align with the slots and holes on the ceiling plate.

2-4. Use a 3” wood screw to pierce two holes in the ceiling gasket that match the pilot holes you drilled in step 2-1.

2-5. read the lead wires from the outlet box down through the hole in the middle of the ceiling gasket and hanger bracket.

Note: e ceiling gasket should be flush against the ceiling.

2-6. Place a flat washer on each of the two 3” wood screws and pass the screws through the slotted holes in the ceiling plate into the pilot holes you drilled.

Tighten the screws into the 9/64” pilot holes; do not use lubricants on the screws. Do not over tighten.

2 • Installing the Ceiling Plate

5

Steps 2-32-5

 

 

Flat Washer

For Angled Ceilings: Be sure to orient

 

 

 

 

the ceiling plate so that the hook and

 

 

 

 

one of the threaded screw holes in the

 

 

3” Wood

ceiling plate are on the lower side.

 

 

 

Screw

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

42701-01 • 01/25/06