INSTALLATION

12

Connect Wires and Mount Thermostat Cover to Wall Plate

Match and connect the labeled wires to the appro- priate coded terminal screws on the wallplate. (See Figure 4, 5.) Ignore any wires which may be present, but which were not connected to the old thermostat.

Refer to the Wiring Diagrams below to be sure your system is wired correctly.

If your system is a single-stage heat pump and uses an O or B wire, you must move the System Selector switch inside the thermostat to the Heat Pump position. If you have a normal furnace or electric system, leave the switch in the Standard position. Refer to the System Selector section on the back for more information on this switch.

Be sure to tighten the terminal screws securely, otherwise a loose wire could cause operational problems with your system or thermostat.

Push excess wire back into the hole to prevent interfer- ence when installing the thermostat to the wallplate.

Make sure the System Switch is set to OFF, and the Fan Switch is set to AUTO.

Insert the bottom tab on the thermostat body into the slot at the bottom of the wallplate. Press the top of the thermostat body to snap it into the wallplate. Refer to Figure 6. (NOTE: Do not force

the thermostat onto the wallplate, as the terminal pins may be damaged. If it does not snap properly, the thermostat may not work.)

Insert the two AA size alkaline batteries, observing the polarity marked inside the battery compartment.

Switch on the main power at the panel or furnace.