5
SRC Controller SmartPort Installation
Access.the.terminal.strip.area.and.attach.the.red.wire.to.the.
left.AC.screw.slot,.attach.the.white.wire.to.the.next.AC.screw.
slot.and.attach.the.blue.wire.to.the.screw.slot.marked.“R”.
Pro-C Controller
SmartPort Installation
Access.the.terminal.strip.area.on.the.
main.module.and.attach.the.red.wire.to.
the.bottom.most.AC.screw.slot,.attach.
the.white.wire.to.the.upper.AC.screw.
slot.and.attach.the.blue.wire.to.the.
screw.slot.marked.“REM”.
ICC Controller SmartPort Installation
Access.the.terminal.
strip.area.on.the.power.
module.and.attach.the.
red.wire.to.the.bottom.
most.AC.screw.slot,.
attach.the.white.wire.
to.the.upper.AC.screw.
slot.and.attach.the.blue.
wire.to.the.screw.slot.
marked.“REM”.
Wiring THe smartport® To Hu nTer conTrollers ..............................
NOTE: Hunter ACC controllers are provided
with the SmartPort® Factory installed.
Red
Blue
White
Blue
White
Red
AC AC R RS C MV 1 2 3 4 5 6
White
Blue
Red