Hunter Fan UH68ODK, UH68ODH manual Operation Under Rainy Conditions, Strike Procedure

Models: UH68ODH UH68ODK

1 29
Download 29 pages 34.59 Kb
Page 16
Image 16
Operation Under Rainy Conditions

UH68 ODK/ODH Tent Heater

Operation Under Rainy Conditions

1.The remote control panel is water-resistant. No special instructions for setting up in the rain.

2.Do not remove protective covers from the remote and power receptacles until ready to connect.

3.To keep rain water from collecting around heater, place heater on skid (1), bricks or small logs. Make sure heater is stable.

4. Paint all chipped and scratched surfaces to

1

prevent rust

Strike Procedure

1.Drain fuel lines

1.While heater is burning, open drain cock (1) on fuel supply line. Let heater run until you hear combustion stop. (burner)

2.Move main switch to OFF and allow heater to cool.

BEFORE PROCEDING MAKE SURE HEATER IS COOLED DOWN AND

DISCONNECTED FROM POWER SUPPLY

3.Close drain cock (1) on supply line. Using a rag or fuel absorbent mat remove supply line from heater at QD fitting. Make sure to hold rag beneath heater QD fitting to catch any fuel left in the fitting.

4.Attach heater QD cover (2).

5.Hold supply line (3) above fuel can and open drain cock (1). Raise as high as possible to let fuel drain into fuel can.

6.Close drain cock (1) and detach supply line from suction feed adapter. Coil up supply line and connect both ends together (4) to keep out dirt.

7.Disconnect overflow line and coil up. Attach QD cover (2)

2.Disconnect ducts (6) and clamps (5), store separate from the heater.(* see duffle bag option for storage)

3.Remove stack, fold PUDA fabric (7) and close PUDA leaving doors open.

2-10

Page 16
Image 16
Hunter Fan UH68ODK, UH68ODH manual Operation Under Rainy Conditions, Strike Procedure, Disconnected From Power Supply