PROBLEM OR CONCERN

7.0 TROUBLESHOOTING

PROBLEM OR CONCERN

POSSIBLE CAUSE

SOLUTION

 

 

 

Detergent Leak

Disconnected or Kinked Deter-

Remove the front cover of the unit and check if the

 

gent Pick up Tube

clear tube is still properly attached or kinked. If it

 

 

is not attached then reconnect it or unkink it.

Reservoir Tank won’t hold

Chemical Tank Nipple Broken

The Chemical Tank Nipple is attached to the inside

Detergent

 

wall of the Reservoir Tank. If it is broken you can

 

 

order a replacement by emailing us at: custome

 

 

rservice@huskypowerwasher.com.

Detergent is not dispensing

Incorrect wand is attached to the

Make sure that the Adjustable wand is attached

 

Gun

to the Gun. Detergent will not dispense with the

 

 

Turbo Wand or at the high pressure setting.

 

Wand is not set the low pressure

Hold the shaft of the Wand in one hand and turn

 

setting

the gray dial all the way clockwise with the other

 

 

hand. If the dial is left even slightly in the counter-

 

 

cockwise direction it will not dispense detergent.

 

Nozzle is clogged with debris

Turn the Nozzle Head until the two metal blades

 

 

move apart completely. Straighten out a paper

 

 

clip and insert it into the tip of the Nozzle. Back

 

 

flush the Nozzle with water. (see section 5.2)

Detergent to Water ratio

 

Your Powerwasher draws detergent at a 10:1

 

 

ratio. Most pressure washer detergents are gene-

 

 

rally concentrated within that range so minimal

 

 

adjustment is required. If you feel like you are

 

 

using more detergent than is required for the ap-

 

 

plication you can dilute it with regular tap water.

Detergent - What to use

 

We recommend that you use a cleaner which is

 

 

specifically designed for power washers. There

 

 

are different kinds available depending on the

 

 

application. Check with your local Home Depot

 

 

store for the product which is best suited for

 

 

your needs.

 

 

Never use Bleach, Ammonia or Hot

 

 

water in the unit.

Detergent Tank fills up with

Detergent Suction Assembly (the

The part will have to be replaced. Please email us

water

part which the High Pressure

directly at customerservice@huskypower

 

hose connects to) is defective

washer.com. You can also order the part di-

 

 

rectly at www.huskypowerwasher.com.

Circuit breaker trips or Fuse

Circuit overload

Check that the circuit is rated at 15 amps or

blown in Fuse Box

 

greater. Make sure the unit is plugged into a

 

 

dedicated circuit.

 

Extension cord too long or wire

Use proper extension cord as recommended in

 

size too small

owner’s manual.

 

Nozzle partially blocked

Clean Nozzle as instructed in section 5.2.

 

Excessive pressure

Clean Nozzle as instructed in section 5.2

GFCI Plug installation

 

For GFCI reset procedures see owner’s manual

 

 

section 3.3. For instructions regarding the GFCI

 

 

Plug installation or malfunction please email us

GFCI Plug malfunction

 

directly at customerservice@huskypowe

 

 

rwasher.com.

23

Page 23
Image 23
Husky 1800 CA manual Problem Or Concern, Possible Cause, Solution, rservice@huskypowerwasher.com, water in the unit